huawei(config-if-tdm-)#
display port state 0
---------------------------------------
Port : 0
State : normal
Mode :
UDT
Code : HDB3
Looptype : -
Timeslot : -
Clock :
system
CRC4 : -
Signaling : -
ESF : -
Impedance : 120 Ohm
---------------------------------------
3.
Query configurations and the status of the system clock source.
Run the
display clock source
command to query configurations and the status of the
system clock source.
huawei(config-if-tdm-)#
quit
huawei(config)#
display clock source
---------------------------------------------------------------
Index Config Type Source State Priority Output
---------------------------------------------------------------
0 YES line 0/0/1 Normal 0 YES
1 NO -- -/ -/ - --- --- ---
2 NO -- -/ -/ - --- --- ---
3 NO -- -/ -/ - --- --- ---
4 NO -- -/ -/ - --- --- ---
5 NO -- -/ -/ - --- --- ---
6 NO -- -/ -/ - --- --- ---
7 NO -- -/ -/ - --- --- ---
8 NO -- -/ -/ - --- --- ---
9 NO -- -/ -/ - --- --- ---
---------------------------------------------------------------
----End
13.3.2.7 Verifying Services
This topic describes how to use the PDH/SDH tester to verify the private line access service.
Prerequisites
The private line service has been configured.
Networking
Figure 13-6
Test setup for E1 upstream service
E1 port
loopback
E1
E1 line tester
Internal
free-run
clock
OLT trace
the clock of
the tester
ONU trace
the clock of
the OLT
OLT
ONU
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
13 FTTO Configuration (Large-sized Enterprise Access)
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1296