Prerequisites
The D-CMTS management policy is set to
extend-frame
. To do so, run the
sysman centralized-
mgmt primary
command.
Context
You can use either of the methods listed in the following table to add a remote extended frame
to an OLT based on site requirements.
Table 15-48
Methods of adding a remote extended frame to an OLT
Method
Usage Scenario
Remarks
Add a remote
extended frame
in offline mode.
The remote extended frames
must be deployed one by one.
This method facilitates remote
extended frame management.
The remote extended frame ID has
been planned.
Add an
automatically
discovered
remote extended
frame.
A great number of remote
extended frames need to be
deployed. This method reduces
manual configurations.
The remote extended frame ID does
not need to be planned.
Data Plan
Table 15-49
Data plan
Item
Data
GE cascading
board
Board: H801ETHB
Port ID: 0/3/1
Remote extended frame ID: 1
NOTE
The OLT uses the MA5603T as an example. The configuration method is the
same for other OLTs. The only difference lies in slot IDs.
Procedure
l
Add a remote extended frame in offline mode.
huawei(config)#
interface eth 0/3
huawei(config-if-eth-0/3)#
network-role extend
This operation will reset the board. Are you sure to continue ? (y/n)[n]:
y
huawei(config-if-eth-0/3)#
quit
huawei(config)#
frame add 1 MA5633 extending-port 0/3/1
l
Add an automatically discovered remote extended frame.
SmartAX MA5600T/MA5603T/MA5608T Multi-service