Figure 17-4
Procedure for configuring intelligent collection of power consumption information
in the electrical power system over Ethernet
Add an ONU to the
OLT
Configure a service channel
between the OLT and the
ONU
Configure a management
channel between the OLT
and the ONU
Start
Save
End
OLT
ONU
Create a VLAN and
add the uplink port to
the VLAN
Create a service port
End
Start
Device
Step
Remarks
OLT
1. Add an ONU on an OLT.
You can configure data for an ONU only
after it has been added on an OLT.
2. Configure a management
channel between the OLT and
the ONU.
After configuring an inband
management channel between the OLT
and the ONU, you can log in to the ONU
on the OLT and configure data for the
ONU.
3. Configure a service channel
between the OLT and the
ONU.
The power consumption information
collected by the ONU is transparently
transmitted by the OLT through the
upper-layer network to the AMR server.
ONU
1. Create a virtual local area
network (VLAN) and add the
uplink port to the VLAN.
To transmit packets with a VLAN tag
through an uplink port, add the uplink
port to the VLAN.
2. Create a service port.
Create a service port on the ONU to
receive the power consumption
information. The data is transmitted
upstream to the OLT through an uplink
port.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
17 Electrical Service Configuration
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1807