Set the management VLAN to 8, GEM port ID to 11, and user VLAN to 8. The OLT does not
rate limit the in-band management service port. Therefore, directly use the default traffic profile
6.
huawei(config)#
service-port vlan 8 gpon 0/3/1 ont 1 gemport 11 multi-service
user-vlan 8 rx-cttr 6 tx-cttr 6
Step 4
Confirm that the connection between the management service ports on the OLT and ONU is
reachable.
l
Run the
ping ONU ip
command on the OLT to verify the connectivity between the OLT and
ONU. If the OLT receives ICMP ECHO-REPLY packets from the ONU, the connection is
reachable.
l
When the connection is reachable, you can remote log in to the ONU from the OLT and
configure the ONU.
----End
14.4.1.5 Configuring TDM E1 Connections
This topic describes how to configure Native TDM connections between GPON ports and E1/
STM-1 upstream ports to transmit E1/STM-1 private line service data.
Prerequisites
Required hardware is available:
l
TOPA+NH1A for upstream transmission through E1
l
TOPA+O2CE for upstream transmission through STM-1
l
GPON board: GPBC, GPBD
Context
The OLT can transmit data to the SDH network through E1 or STM-1 lines. Each E1 line provides
2 Mbit/s bandwidth. After being mapped, aligned, and encapsulated, 63xE1 signals are
multiplexed into one STM-1 signal through VC12. One STM-1 line provides 155 Mbit/s.
When the OLT transmits data to SDH equipment through STM-1 lines, pay attention to the VC12
mode and VC12 number.
l
When the OLT is interconnected with Huawei SDH equipment, the VC12 mode is huawei
and the VC12 numbers on the OLT and the SDH equipment must be consistent.
l
When the OLT is interconnected with Lucent SDH equipment, the VC12 mode is lucent.
The VC12 numbers has the following mapping relationships (which can be queried using
the
display vc12-mode-table
command):
Huawei: Mapping between the multiplexing number and VC12 number: VC12 number =
(TUG3–1) + (TUG2–1) x 3 + (TU12–1) x 21
Lucent: Mapping between the multiplexing number and VC12 number: VC12 number =
(TU12–1) + (TUG2–1) x 3 + (TUG3–1) x 21
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
14 FTTM Configuration (Base Station Access)
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1405