Step 8
Save the data.
huawei(config)#
save
----End
Result
After the SIP interface is interconnected with the IMS successfully, you can run the
display if-
sip all
command to confirm that the SIP interface is in the normal state.
huawei(config)#
display if-sip all
--------------------------------------------------------
MGID TransMode State SignalPort SignalIP
--------------------------------------------------------
0 UDP
Normal
5555 10.50.1.10
--------------------------------------------------------
Configuration File
vlan 50 smart
port vlan 50 0/19 0
interface vlanif 50
ip address 10.50.1.10 24
quit
voip
ip address media 10.50.1.10 10.50.1.1
ip address signaling 10.50.1.10
quit
ip route-static 10.10.1.0 255.255.255.0 10.50.1.1
interface sip 0
y
if-sip attribute basic media-ip 10.50.1.10 signal-ip
10.50.1.10 signal-port 5555 transfer udp primary-proxy-ip1 10.10.1.1 primary-proxy-
port 5555
secondary-proxy-ip1 10.10.1.2 secondary-proxy-port 5555 home-domain MA5600T/
MA5603T/MA5608T.com sipprofile-index 0
if-sip attribute optional mg-domain huawei.com phone-c86755
reset
y
quit
save
1.4.6 Commissioning the Management Channel Between the OLT
and the GPON MDU
This topic describes how to commission the management channel between the MA5600T/
MA5603T/MA5608T and the GPON MDU to ensure that you can log in to the GPON MDU
using the MA5600T/MA5603T/MA5608T at the CO to remotely maintain and manage the
GPON MDU.
Service Requirements
In the network as shown in
, the service requirements are as follows:
l
A GPON port on the MA5600T/MA5603T/MA5608T is connected to 128 MDUs using an
optical splitter.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
1 Commissioning
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
174