Item
Data
configuration
on the MGC.)
User data
Phone number
The emergency standalone is not
supported, and therefore the
configuration of phone numbers is not
required when the users are added.
The MGC assigns phone numbers
83110000-83110031 to phones 0-31
respectively.
TID
The terminal layering is supported, and
therefore the manual allocation of TIDs
is not required.
User priority
The users are common users, and the
user priority uses the default cat3.
User type
The users are common users, and the
users are of the default DEL type.
System parameters
According to the Background
Information in (Optional) Configuring
the System Parameters and confirmed
with the service provider, the default
settings can meet the service
requirements. Therefore, the system
parameters are not configured here.
Overseas parameters
According to the Background
Information in (Optional) Configuring
the Overseas Parameters and confirmed
with the service provider, the default
settings can meet the service
requirements. Therefore, the overseas
parameters are not configured here.
PSTN port attributes
The polarity reversal accounting is
adopted, and therefore the PSTN port to
which the users belong needs to support
the polarity reversal pulse. The other
attributes of the PSTN port do not need
to be modified.
Ringing current attributes
There is no special requirement, and the
configuration of the ringing current
attributes is not required.
Procedure
Step 1
Add the upstream VLAN interface.
According to the data plan, configure standard VLAN 20 as the media and signaling upstream
VLAN, add upstream port 0/19/0 to the VLAN, and configure the IP address of the Layer 3
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
3 Configuring the DSLAM Services
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
305