background image

LoRaWAN

®

Controller

UC50x Series

User Guide

Содержание UC50 Series

Страница 1: ...LoRaWAN Controller UC50x Series User Guide...

Страница 2: ...hocks or impacts Declaration of Conformity UC50x series is in conformity with the essential requirements and other relevant provisions of the CE FCC and RoHS Copyright 2011 2022 Milesight All rights r...

Страница 3: ...4 Operation Guide 8 4 1 Log in the ToolBox 8 4 1 1 NFC Configuration 8 4 1 2 USB Configuration 9 4 2 LoRaWAN Settings 10 4 3 Interface Settings 13 4 3 1 RS485 Settings 14 4 3 2 RS232 Settings 17 4 3 3...

Страница 4: ...ust in harsh environments 1 2 Features Easy to connect with multiple wired sensors through GPIO AI RS232 RS485 interfaces Long transmission distance up to 11km with line of sight Waterproof design inc...

Страница 5: ...Pin Description 1 5V 9V 12V Switchable 2 3 3V 3 GND 4 GPIO1 5 GPIO2 6 RS232 RS485 Switchable 7 8 Reserved Pin RS232 RS485 6 TXD A 7 RXD B Data Interface 2 Pin Description 1 5V 9V 12V Switchable 2 3 3...

Страница 6: ...ff 2 on 3 on 0 10V ADC 1 on 2 off 3 off RS485 Add 120 resistor between A and B 1 on 2 off 3 off Add 1k pull up resistor on A 1 off 2 on 3 off Add 1k pull down resistor on B 1 of 2 off 3 on Note 1 Anal...

Страница 7: ...Light On Device is on Light Off Device is off 2 4 Dimensions mm 3 Hardware Switch When using the analog input or power output of UC50x series please follow the steps to switch the working mode of har...

Страница 8: ...ble NFC on the smartphone and launch Milesight ToolBox 3 Attach the smartphone with NFC area to the device to read device information 4 Basic information and settings of the device will be shown on To...

Страница 9: ...dedicated NFC reader which can be purchased from Milesight IoT 4 1 2 USB Configuration 1 Download ToolBox software from Milesight IoT website 2 Open the case of UC50x and connect the UC50x to compute...

Страница 10: ...ing the transmission parameters in LoRaWAN network Basic LoRaWAN Settings Go to LoRaWAN Basic of ToolBox software or Setting LoRaWAN Settings for ToolBox App to configure join type App EUI App Key and...

Страница 11: ...g Mode UC501 Class A and Class C are available UC502 Class A Join Type OTAA and ABP mode are available Application Key Appkey for OTAA mode default is 5572404C696E6B4C6F52613230313823 Device Address D...

Страница 12: ...er of the device Note 1 Please contact sales for device EUI list if there are many units 2 Please contact sales if you need random App keys before purchase 3 Select OTAA mode if you use Milesight IoT...

Страница 13: ...n by multiple interfaces including GPIOs analog inputs and serial ports Besides it can also power the terminal devices by power output interfaces Basic settings are as follows Go to General Basic of T...

Страница 14: ...1 If you need UC50x to power this device please connect the power cable to 5V 9V 12V or 3 3V power output on interface 1 2 Go to General Serial of ToolBox software or Setting Serial Setting to enable...

Страница 15: ...UC50x waits for the reply to the command If it does not get a response after the max response time it is determined that the command has timed out Max Retry Time Set the maximum retry times after devi...

Страница 16: ...00 00 01 84 0A 4 For ToolBox software click Fetch to check if UC50x can read correct data from terminal devices You can also click Fetch on the top of list to fetch all channel data Note Please do not...

Страница 17: ...1 2 Go to General Serial of ToolBox software or Setting Serial Setting to enable RS232 and configure serial port settings Serial port settings should the same as RS232 terminal devices Parameters Desc...

Страница 18: ...available Data Bit 8 bit is available Stop Bit 1 bit 2 bit are available Parity None Odd and Oven are available Port The port used for RS232 data transmission 4 3 3 GPIO Settings 1 Connect devices to...

Страница 19: ...Switch to check if UC50x can trigger devices by digital output or click Fetch to check current status of digital output Pulse Counter Parameters Description Digital Input Initial status of counter Pu...

Страница 20: ...device to power output on interface 2 2 Go to General AI of ToolBox software or Setting AI Setting to enable analog input and select the analog type Note Ensure DIP switches has changed before changi...

Страница 21: ...e collect data b Click Fetch and attach smart phone to make APP read the data 4 4 Maintenance 4 4 1 Upgrade ToolBox Software 1 Download firmware from www milesight iot com to your PC 2 Go to Maintenan...

Страница 22: ...e upgrade 2 Only Android version ToolBox supports the upgrade feature 4 4 2 Backup UC50x devices support configuration backup for easy and quick device configuration in bulk Backup is allowed only for...

Страница 23: ...to import the configurations ToolBox App 1 Go to Template page on the APP and save current settings as a template You can also edit the template file 2 Select one template file which saved in the sma...

Страница 24: ...set device Via Hardware Open the case of UC50x and hold on power button more than 10s Via ToolBox Software Go to Maintenance Backup and Reset to click Reset Via ToolBox App Go to Device Maintenance to...

Страница 25: ...emove the mounting bracket from the wall Note The connecting lines of adjacent points are at right angles 3 Drill the four holes by using your drill with a 6 mm drill bit on the positions you marked p...

Страница 26: ...naged by Milesight IoT Cloud platform Milesight IoT cloud is a comprehensive platform that provides multiple services including device remote management and data visualization with the easiest operati...

Страница 27: ...type the same as device settings 4 After UC50x is online in Milesight IoT Cloud click and go to Interface Settings to select used interfaces and customize the name sign and formulas Note Modbus channe...

Страница 28: ...Device Payload UC50x Series use the standard Milesight IoT payload format based on IPSO Please refer to the UC50x Series Communication Protocol for decoders of Milesight IoT products please click here...

Отзывы: