FEATURES
TECHNICAL DATA
DESCRIPTION
• 3,2” LCD display
• Operation by means of touch buttons
• Anti-freezing function
• Floor overheating protection
• Key lock function
•
Programmable temperature controller
cooperates with the inner floor sensor or
with both sensors simultaneously floor
sensor operates as the (floor temperature
limiter)
RTD-02 is a 7-day programmable Control-
ler designed to control temperature in electric
fl oor heating systems. It is operated by means
of touch buttons placed under the screen.
The Controller is mounted on a wall in a ¢60 x 60 mm
deepened junction box.
RTD-02
Input (supply) terminals: N (3), L (4)
Power supply voltage: 95~240VAC
Nominal frequency: 50/60Hz
Nominal current consumption: < 0,55W (STANDBY switched off relay and backlight)
Battery backup: no
NTC sensor terminals: (5), (6)
Temperature sensor: NTC 10k for 25°C, 2,5m
Room temperature range: +5 ÷ +35°C
Floor temperature range: +5 ÷ +35°C
Operating temperature range: 5 ÷ +45°C
Temperature range during transport: -5 ÷+55°C
Temperature measurement accuracy: 1°C
Resolutions of temperature indications: 0,5°C
Hysteresis: 1-2-3-4-5°C (default 1°C)
Output terminals: (1), (2)
Output type: voltage contact 1NO-16 A/250 V AC
Number of terminal clamps: 6
Cross-section of connecting cables: 0,5÷2,5 mm
2
Humidity: 5-90%, non-condensing
Mounting: deepen junction box ¢ 60mm x 60mm
Casing material: PC+ABS
Casing protection degree: IP20
Protection class: II
Overvoltage category: II
Application environment with pollution degree 2 intended for domestic use of normal air circulation
Dimensions: 86 x 86 x 13,3/39 mm (H x W x D)
Weight: 165g
Reference standards: EN 60950-2: 2006+A11:2009+A1:2010+A12:2011+
A2:2013 EN 61000-6-3:2007+A1: 2011+AC:2012
EN 61000-6-1:2007
EN61000-3-2:2006+A1: 2009+A2:2009
EN 61000-3-3:2013
PN-EN 61000-4-3
PN-EN 61000-4-11
PN-EN 61000-4-6
Item
Function
Settings and options
Default
settings
6
Key lock
0 - All keys are locked except the power supply key.
1 - All keys are locked
0
7 (1)
Week option selection
0 – heating cycle time period in the 1-2-3-4-5 and 6-7 1 week – heating cycle time period in
the 1-2-3-4-5-6 and 7 week.
1
7 (2)
Communication protocol
Store option 0.
Option 1 does not refer to the software including the controller’s functionality.
0
8
Clock 12/24h
12h - mode 12-hour AM/PM 24h - mode 24-hour
24h
9
Backlight time
Select time 3-99 seconds
10
10
Intelligent start-up
00 – programming the heating time
01- heating control in advance – it starts 30 minutes in advance to the pre-set time periods.
0
11
Return to factory settings
Press for settings in points rst 1 to rst 9.
Press again to return to the default settings.
If sensors are in the AI mode (temperature sensor and floor sensor), it is possible to check the floor temperature by pressing the and
buttons for 3 seconds.
Controler’s lock
Press the
buttons for 5 seconds to lock / unlock the keys.
Caution
The symbol means selective collecting of electrical and electronic equipment.
It is forbidden to put the used equipment together with other waste.
CONTROLLER DESCRIPTIONS
Key lock symbol
Day of the week Temperature
Period
Morning / Afternoon
Time
Inner sensor temperature control
Temperature setting
Manual mode operation manual
Operating mode change:
manual / automatic
Parameter adjustment
Clock adjustment /
Programme adjustment
Controller switching on
/ switching off
Inner sensor temperature control
WARRANTY CARD
There is a 24 month guarantee on the product
Salesman stamp and signature, date of sale
1. ZAMEL Sp. z o.o. assures a 24 month guarantee for the product.
2. The manufacturer’s guarantee does not cover any of the following actions:
a) mechanical damage during transport, loading / unloading or under other circumstances,
b) damage caused by incorrect product mounting or misuse,
c) damage caused by unauthorised modifi cations made by the PURCHASER or any third parties to the product or any other devices
required for the product functioning,
d) damage caused by Act of God or any other incidents independent of the manufacturer – ZAMEL Sp z o.o.
3. The PURCHASER shall lay any claims in writing in the place of purchase or to ZAMEL Sp. z o.o.
4. ZAMEL Sp. z o.o. is liable for processing any claim according to current Polish legislation.
5. ZAMEL Sp. z o.o. shall process the claim at its own discretion: product repair, replacement or money return.
6. The manufacturer’s guarantee is valid in the Republic of Poland.
7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or otherwise
are not affected by this warranty.
Automatic mode operation
acc. to the programme
Heating switched on
Floor sensor temperature control