FEATURES

TECHNICAL DATA

DESCRIPTION

• 3,2” LCD display
• Operation by means of touch buttons
• Anti-freezing function
• Floor overheating protection
• Key lock function
•  

Programmable temperature controller
cooperates with the inner floor sensor or
with both sensors simultaneously floor
sensor operates as the (floor temperature
limiter)

RTD-02 is a 7-day programmable Control-

ler designed to control temperature in electric 
fl oor heating systems. It is operated by means 
of touch buttons placed under the screen. 
The Controller is mounted on a wall in a ¢60 x 60 mm 
deepened junction box.

RTD-02

Input (supply) terminals:  N (3), L (4)

Power supply voltage:  95~240VAC

Nominal frequency:  50/60Hz

Nominal current consumption:  < 0,55W (STANDBY switched off relay and backlight)

Battery backup:  no

NTC sensor terminals:  (5), (6)

Temperature sensor:  NTC 10k for 25°C, 2,5m

Room temperature range:  +5 ÷ +35°C

Floor temperature range:  +5 ÷ +35°C

Operating temperature range:  5 ÷ +45°C

Temperature range during transport:  -5 ÷+55°C

Temperature measurement accuracy:  1°C

Resolutions of temperature indications:  0,5°C

Hysteresis:  1-2-3-4-5°C (default 1°C)

Output terminals:  (1), (2)

Output type:  voltage contact 1NO-16 A/250 V AC

Number of terminal clamps:  6

Cross-section of connecting cables:  0,5÷2,5 mm

2

Humidity:  5-90%, non-condensing

Mounting:  deepen junction box ¢ 60mm x 60mm

Casing material:  PC+ABS

Casing protection degree:  IP20

Protection class:  II

Overvoltage category:  II

Application environment with pollution degree 2  intended for domestic use of normal air circulation

Dimensions:  86 x 86 x 13,3/39 mm (H x W x D)

Weight:   165g

Reference standards:  EN 60950-2: 2006+A11:2009+A1:2010+A12:2011+

 A2:2013 EN 61000-6-3:2007+A1: 2011+AC:2012

 EN 61000-6-1:2007

 EN61000-3-2:2006+A1: 2009+A2:2009

 EN 61000-3-3:2013

 PN-EN 61000-4-3

 PN-EN 61000-4-11

 PN-EN 61000-4-6

Item

Function

Settings and options 

Default

settings

6

Key lock

0 - All keys are locked except the power supply key.

1 - All keys are locked

0

7 (1)

Week option selection

0 – heating cycle time period in the 1-2-3-4-5 and 6-7 1 week – heating cycle time period in 

the  1-2-3-4-5-6 and 7 week.

1

7 (2)

Communication protocol

Store option 0.

Option 1 does not refer to the software including the controller’s functionality.

0

8

Clock 12/24h

12h - mode 12-hour AM/PM 24h - mode 24-hour

24h

9

Backlight time

Select time 3-99 seconds

10

10

Intelligent start-up

00 – programming the heating time

01- heating control in advance – it starts 30 minutes in advance to the pre-set time periods.

0

11

Return to factory settings

Press   for settings in points rst 1 to rst 9.

Press   again to return to the default settings.

If sensors are in the AI mode (temperature sensor and floor sensor), it is possible to check the floor temperature by pressing the   and 

buttons for 3 seconds.

Controler’s lock

Press the 

 buttons for 5 seconds to lock / unlock the keys.

Caution

The symbol means selective collecting of electrical and electronic equipment. 

It is forbidden to put the used equipment together with other waste.

CONTROLLER DESCRIPTIONS

Key lock symbol

Day of the week Temperature

Period

 Morning / Afternoon

 Time

Inner sensor temperature control 

Temperature setting

Manual mode operation manual

Operating mode change: 

manual / automatic

Parameter adjustment

Clock adjustment / 

Programme adjustment

Controller switching on 

/ switching off 

Inner sensor temperature control 

WARRANTY CARD

There is a 24 month guarantee on the product

Salesman stamp and signature, date of sale

1. ZAMEL Sp. z o.o. assures a 24 month guarantee for the product.

2. The manufacturer’s guarantee does not cover any of the following actions:

a) mechanical damage during transport, loading / unloading or under other circumstances,

b) damage caused by incorrect product mounting or misuse,

c) damage caused by unauthorised modifi cations made by the PURCHASER or any third parties to the product  or any other devices

required for the product functioning,

d) damage caused by Act of God or any other incidents independent of the manufacturer – ZAMEL Sp z o.o.

3. The PURCHASER shall lay any claims in writing in the place of purchase or  to ZAMEL Sp. z o.o.

4. ZAMEL Sp. z o.o. is liable for processing any claim according to current Polish legislation.

5. ZAMEL Sp. z o.o. shall process the claim at its own discretion: product repair, replacement or money return.

6. The manufacturer’s guarantee is valid in the Republic of Poland.

7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or otherwise

are not affected by this warranty.

 

Automatic mode operation 

acc. to the programme

Heating switched on  

Floor sensor temperature control