Precautions
1.
An ONU supports both the H.248 and SIP protocols; however, these two protocols are
mutually exclusive. You can run the
display protocol support
command to query the
currently supported voice protocol.
2.
If the voice protocol needs to be switched, you need to delete the MG interface first and
run the
protocol support
command to switch the protocol. After the configuration is
complete, save the configuration and restart the system to make the configured protocol
take effect.
CAUTION
This operation interrupts the ongoing services carried on the currently used MG interface. Hence,
exercise caution when performing this operation.
Data Plan
For configuration rules and description of configuration items, see
.
Item
Data
SIP
interface
data
NOTE
(It must be
the same as
that on the
IMS core
network
device.)
Media
and
signalin
g
paramet
ers
Media and
signaling upstream
VLAN
200
Media and
signaling upstream
port
0/0/1
Media IP address
and signaling IP
address
10.10.10.10/24
Default gateway
IP address
10.10.10.1/24
SIP interface ID
0
Signaling port ID
5060
IP address of the main IMS
equipment
200.200.200.200/24
Port ID of the main IMS
equipment
5060
Coding scheme
Text
Transmission mode
UDP
Home domain name (SIP)
huawei
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
11 FTTB and FTTC Solution Configuration
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
873