Item
Data
Remarks
Tunnel
Tunnel ID: 20; tunnel interface ID:
20
Encapsulation protocol of the tunnel
interface at the data link layer:
MPLS IP
Source IP address of the tunnel:
5.5.5.5
Destination IP address of the tunnel:
7.7.7.7
IP tunnels are used.
Ingress and egress addresses of a
tunnel are the LSR IDs of the local
device and the peer PE device,
respectively.
OSPF
OSPF process ID: 200; OSPF area
ID: 1
Routes use the OSPF protocol.
PWE3
gateway
LSR ID: 7.7.7.7
It is the LSR ID of the peer PE
device.
Table 4-4
Plan for configuring attributes of each type of service
Item
service Type
Remarks
UBR
VBR
CBR
Board
Slot
0/2
0/3
0/4
Multiple services of the same type
but from different users are
deployed at different ports on the
same board (in the same slot). By
doing so, the same PW is used to
carry multiple PVCs. This
improves the transmission
efficiency, reduces the number of
PWs required, and facilitates the
application of QoS policies.
Services of different types are
deployed on boards in different
slots, isolating the services
physically.
VPI/
VCI of
Cells
0/35
0/35
0/35
Since the services belong to the
same ISP, the VPI/VCI parameters
of cells on PVCs at different ports
are the same.
Bindin
g PW
ID
20
21
22
Services of different types are
carried over different PWs,
eliminating service interaction.
SmartAX MA5600T/MA5603T/MA5608T Multi-service