Run the
ont-alarm-policy
command to create an ONT alarm policy profile.
The system supports a maximum number of 16 alarm policy profiles. The default
alarm policy profile is profile 0.
It is recommended that you configure different alarm policies for VIP and common
users.
2.
Configure attributes of the ONT alarm policy profile.
Run the
alarm filter
command to configure the control function of each alarm of the
profile.
Run the
commit
command to save the configuration.
Run the
display ont-alarm-policy
command to query attributes of the ONT alarm
policy profile.
3.
Bind the ONT to the ONT alarm policy profile.
Run the
ont alarm-policy
command to bind the ONT to the ONT alarm policy profile
so that the PON board can control whether to send the ONT alarm information.
During ONT adding or confirmation, the system binds the ONT to the default ONT
alarm policy profile 0.
----End
Example
Assume the following configurations: The output of all alarms at level
warning
is shielded to
the CLI terminal, the alarm jitter-proof function is enabled, the alarm jitter-proof period is set
to 15s, the level of alarms with IDs 0x0a310021 and 0x2e314021 are modified to
critical
, do as
follows:
huawei(config)#
undo alarm output alarmlevel warning
huawei(config)#
alarm jitter-proof on
huawei(config)#
alarm jitter-proof 15
huawei(config)#
alarm alarmlevel 0x0a310021 critical
huawei(config)#
alarm alarmlevel 0x2e314021 critical
To mask the activation and deactivation alarm events of the ADSL port (event IDs 0x0a300013
and 0x0a300015) so that normal operations are not affected by too many alarms, do as follows:
huawei(config)#
undo event output eventid 0x0a300013
huawei(config)#
undo event output eventid 0x0a300015
To create ONT alarm policy profile 10, filter the following alarms, and bind this profile to GPON
ONT 1 connected to port 0/3/0, do as follows:
l
0x2e112003 (The signal degrade of ONTi (SDi) occurs)
l
0x2e112004 (The signal fail of ONTi (SFi) occurs)
l
0x2e112006 (The loss of frame of ONTi (LOFi) occurs)
l
0x2e313015 (The hardware of the ONT is faulty)
l
0x2e313016 (The ONT switches to the standby battery)
l
0x2e313017 (The standby battery of the ONT is lost)
l
0x2e313018 (The standby battery of the ONT cannot be charged)