Item
Data Plan for the F01S300 Cabinet
Environment
monitoring
parameters
Upper alarm threshold of the temperature: 68°C
Lower alarm threshold of the temperature: -5°C
Upper test threshold of the humidity: 80°C
Lower test threshold of the humidity: -20°C
External extended
digital parameters
Digital parameter ID: 0
This digital parameter is set according to the actual requirements. The
monitoring digital parameter of the external fan tray is set here to
monitor the fan tray. When the fan tray is faulty, the host reports an
alarm.
Valid level of digital parameter 0: low level
When the low level represents the valid level, the host does not report
an alarm in the case of low level.
Digital parameter ID: 1
This digital parameter is set according to the actual requirements. The
monitoring digital parameter of the external fan tray is set here to
monitor the fan tray. When the fan tray is faulty, the host reports an
alarm.
Valid level of digital parameter 1: low level
When the low level represents the valid level, the host does not report
an alarm in the case of low level.
Digital parameter ID: 2
This digital parameter is set according to the actual requirements.
Valid level of digital parameter 2: low level
When the low level represents the valid level, the host does not report
an alarm in the case of low level.
Digital parameter ID: 3
This digital parameter is set according to the actual requirements. The
monitoring digital parameter of the surge protector is set here to monitor
the status of the surge protector. When the surge protector is faulty, the
host reports an alarm.
Valid level of digital parameter 3: low level
When the low level represents the valid level, the host does not report
an alarm in the case of low level.