CAUTION
This operation interrupts the ongoing services carried on the currently used MG interface. Hence,
exercise caution when performing this operation.
Data plan
For details about the data plan, see
11.2.5 Principle of VoIP Service Data Plan
.
Item
Data
MG
interface
data
NOTE
The data
configurati
on must be
the same as
the data
configurati
on on the
MGC.
Media
and
signalin
g
paramet
ers
Media and signaling
upstream VLANs
200
Media and signaling
upstream port
0/0/1
Media IP address and
signaling IP address
10.10.10.10/24
Default gateway IP address 10.10.10.1/24
MG interface ID
0
Signaling port ID
2944
IP address of the primary MGC
200.200.200.200/24
Port ID of the primary MGC
2944
Coding
Text
Transmission mode
UDP
H248 version that MG starts to
negotiate
1 (the negotiation starts from V1)
Voice user
configuratio
n data
Phone number
83110001-83110024
Terminal identification
Terminal layering is not supported
and the terminal identification
ranges from 0 to 23.
User priority
Cat2 for phone 1
Cat3 for phone 2 to phone 24
(default)
User type
Common user (DEL user by default)
Common
parameter
System parameter
Default value
Overseas parameter
Default value
PSTN port attribute
Polarity-reversal
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
11 FTTB and FTTC Solution Configuration
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
909