1.
Create an S-VLAN and add an upstream port to it.
Create S-VLAN 1000 with the common attribute and add upstream port 0/19/0 to the
S-VLAN.
huawei(config)#
vlan 1000 smart
huawei(config)#
port vlan 1000 0/19 0
2.
Create a multicast service port.
Configure a service port with the user VLAN being 1000. The HGW is connected to
port 1/1/0 of the GE remote extended subrack. Upstream and downstream traffic is
rate-limited using a line profile. A traffic profile (traffic profile 10 in this example)
that does not limit rates is referenced.
huawei(config)#
service-port vlan 1000 vdsl mode ptm 1/1/0 multi-service
user-vlan 1000 rx-cttr 10 tx-cttr 10
3.
Set the IGMP version.
Set the IGMP version to IGMP v3.
huawei(config)#
multicast-vlan 1000
huawei(config-mvlan1000)#
igmp version v3
4.
Set the IGMP mode.
Set the IGMP mode to IGMP proxy.
huawei(config-mvlan1000)#
igmp mode proxy
Are you sure to change IGMP mode?(y/n)[n]:
y
5.
Configure the multicast upstream port.
Configure the IGMP upstream port as 0/19/0.
huawei(config-mvlan1000)#
igmp uplink-port 0/19/0
6.
Configure multicast programs.
Set the IP address of multicast programs to 224.1.1.10–224.1.1.100, and IP address
of the multicast server to 10.10.10.10.
huawei(config-mvlan1000)#
igmp program add batch ip 224.1.1.10 to-ip
224.1.1.100
sourceip 10.10.10.10
----End
11.4.2.7 (Optional) Configuring Vectoring
Vectoring configurations on VDSL2 lines cancel the far-end crosstalk (FEXT) of VDSL2 lines
to improve the line rate.
Context
For MA5623AR, when configuring vectoring, learn configuration item functions and
configuration methods beforehand by referring to
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
11 FTTB and FTTC Solution Configuration
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1053