Data Plan
Item
Data
Ethernet upstream
board
Port: 0/19/0
NOTE
The SPUF board exclusively occupies a service slot. This topic uses the GIU
upstream board as an example.
Procedure
l
Configure the OLT-side clock.
1.
Configure a system clock source.
Use the Ethernet line clock input from GIU port 0/19/0 as the system clock. Set the
index of the system clock to
0
and priority to
0
(highest priority).
huawei(config)#
clock source 0 0/19/0
huawei(config)#
clock priority system 0
2.
Query the configurations and status of the system clock source.
Run the
display clock source system
command to query the configurations and status
of the clock source. Ensure that the configurations of the system clock source are
correct and the status of the system clock source is
Normal
.
huawei(config)#
display clock source system
-------------------------------------------------------------------------
-----
Index Board Source Clk-type State Priority QL
Selected
-------------------------------------------------------------------------
-----
0 H801GICK 0/19/0 ETH
Normal
0 ---
YES
-------------------------------------------------------------------------
-----
Run the
display clock mode
command to query the working mode of the clock. Ensure
that the working mode of the clock daughter board is
Tracing
.
huawei(config)#
display clock mode
Clock manage-mode:Third-mode
Clock subboard work-mode:
Tracing
l
Configure the ONU-side clock.
1.
Configure the PON line clock as the system clock.
huawei(config)#
clock source 0 0/0/1
huawei(config)#
clock priority system 0
2.
Query the configuration and status of the system clock source.
Run the
display clock source
command to query the configuration and status of the
system clock source.
huawei(config-if-tdm-0/1)#
quit
huawei(config)#
display clock source
--------------------------------------------------------------------
Index Type Source State Priority QL Selected
--------------------------------------------------------------------
0 line 0/0/1 Normal 0 --- YES
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
14 FTTM Configuration (Base Station Access)
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1494