POTS port profile: saves physical attributes of a POTS port on an ONU, including the
impedance, transmitting gain, receiving gain, and signaling type of the POTS port.
1.
Configure an interface common profile.
Run the
display ont-mg-attribute-profile
command to query the existing interface
common profile in the system. If the existing interface common profile in the system does
not meet the requirements, run the
ont-mg-attribute-profile add
command to add an
interface common profile.
In this example, the default interface common profile, namely interface common profile 1
is used.
2.
Configure an MGC interface profile.
Run the
display ont-mgc-profile
command to query the existing MGC interface profile in
the system. If the existing MGC interface profile in the system does not meet the
requirements, run the
ont-mgc-profile add
command to add an MGC interface profile.
Create MGC interface profile 2, set the IP address of the MGC to 200.200.200.200, and
use default values for other parameters.
huawei(config)#
ont-mgc-profile add profile-id 2 primary-mgc 200.200.200.200
3.
Configure a POTS port profile.
Run the
display ont-pots-profile
command to query the existing POTS port profile in the
system. If the existing POTS port profile in the system does not meet the requirements, run
the
ont-pots-profile add
command to add a POTS port profile.
In this example, the default POTS port profile, namely POTS port profile 1 is used.
Step 4
Configure the IP addresses of ONU SIP users.
For ONU 1 and ONU 2, configure the IP address obtaining mode to the static mode, set the IP
addresses to 10.10.10.10/24 and 10.10.10.20/24, set the management VLAN to VLAN 20, and
use default values for other parameters.
huawei(config)#
interface gpon 0/1
huawei(config-if-gpon-0/1)#
ont ipconfig 0 1 dhcp vlan 20
huawei(config-if-gpon-0/1)#
ont ipconfig 0 2 dhcp vlan 20
Step 5
Configure H.248 POTS users.
1.
Add an H.248 interface and apply an MGC interface profile to the interface.
For ONU 1 and ONU 2, set the MG ID to 1, apply MGC interface profile 2 to ONU 1 and
ONU 2, and use default values for other parameters.
If parameters of an MGC interface profile are changed, the MGC interface profile must be
reapplied to the ONU so that the changed parameters can take effect.
huawei(config-if-gpon-0/1)#
if-h248 add 0 1 1 mgc-profile profile-id 2
huawei(config-if-gpon-0/1)#
if-h248 add 0 2 1 mgc-profile profile-id 2
2.
Add POTS users.
For ONU 1 and ONU 2, create a POTS user, set the MG ID to 1 (identical to the MG ID
of the H.248 interface), and set the physical terminal port ID to A0 and A1.
huawei(config-if-gpon-0/1)#
mgpstnuser add 0 1 1 mgid 1 terminalid A0
huawei(config-if-gpon-0/1)#
mgpstnuser add 0 2 1 mgid 1 terminalid A1
Run the
display mgpstnuser attribute
command to check whether the configuration of
the POTS user is properly set.
huawei(config-if-gpon-0/1)#
display mgpstnuser attribute 0 1 1
------------------------------------------------------------------------------
F/S/P : 0/1/0
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
12 FTTO Configuration(SOHO and SME)
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1161