Figure 3-10
Example network for configuring the MGCP-based VoIP service
Prerequisite
l
According to the actual network, a route from the MA5600T/MA5603T/MA5608T to the
MGC must be configured to ensure that the MA5600T/MA5603T/MA5608T and the MGC
are reachable from each other.
l
Electronic switch 0 must be in
location-1
(indicating that the system goes upstream through
only the upstream board). Electronic switch 1 must be in
location-0
(indicating that the
VoIP service is supported). For details about how to configure the electronic switch, see
electro-switch
.
NOTE
l
The SCUN and SCUH control boards do not support electronic switch.
l
The control board SCUL does not provide the upstream port and the system goes upstream
through only the upstream board.
l
The POTS service board, namely the ASPB board, must be inserted into the planned slot,
and the RUN ALM LED of the board must be green and must be on for 1s and off for 1s
repeatedly.