In this example, the default SIP service data profile, namely SIP service data profile 1 is
used.
3.
Apply a POTS port profile.
Run the
pstnport electric
command to apply a POTS port profile to an SIP interface or
configure the interface customized parameters, or run the
ont-pstnport electric bat-
apply
command to bulk apply the POTS port profiles to SIP interfaces. If you use these
two commands to apply the POTS port profiles or configure the interface customized
parameters repeatedly, the last configurations take effect.
In this example, the default POTS port profile, namely POTS port profile 1 is used.
4.
Bind a digitmap profile.
Run the
sippstnuser digitmap
command to bind a digitmap profile to an SIP interface, or
run the
ont-sippstnuser bat-bind from
command to bulk apply the digitmap profiles to
SIP interfaces. If you use these two commands to bind the SIP service data profiles to SIP
ports repeatedly, the last configurations take effect.
In this example, the default digitmap profile, namely digitmap profile 1 is used.
Step 10
(Optional) Configure the SIP user codec.
Run the
sippstnuser codec
command to configure the SIP user codec. The SIP user codec will
not be configured independently in this example.
Step 11
Save the data.
huawei(config)#
save
----End
9.7.1.9 Configuring the BTV Service
The OLT is connected to the remote bridging ONT through a GPON port to provide users with
the multicast service.
Prerequisites
l
The OLT is connected to the BRAS and the multicast source.
l
The VLAN of the LAN switch port connected to the OLT is the same as the upstream
VLAN of the OLT.
l
The ONT has been added to the OLT. For details, see
Data Plan
Table 9-3
Data plan
Item
Data
ONT line profile
Profile name: ftth
T-CONT ID: 4
GEM port ID: 13
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
9 FTTH Configuration
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
616