7
Operating modes
188
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Object 6081
h
: profile_velocity
The object profile_velocity specifies the speed that is normally reached at the end of the acceleration
ramp during positioning. The object profile_velocity is specified in speed units.
Index
6081
h
Name
profile_velocity
Object Code
VAR
Data Type
UINT32
Access
rw
PDO mapping
yes
Units
speed units
Value Range
–
Default Value
1000
Object 6082
h
: end_velocity
The object end_velocity (end speed) defines the speed the drive must have when it reaches the target
position (target_position). Normally, this object must be set to zero so that the motor controller stops
when it reaches the target position (target_position). For continuous positioning, a speed different
from zero can be specified. The object end_velocity is specified in the same units as the object
profile_velocity.
Index
6082
h
Name
end_velocity
Object Code
VAR
Data Type
UINT32
Access
rw
PDO mapping
yes
Units
speed units
Value Range
–
Default Value
0
Object 6083
h
: profile_acceleration
The object profile_acceleration specifies the acceleration with which the motor accelerates to the
nominal value. It is specified in user-defined acceleration units (
Conversion factors (factor group)).
Index
6083
h
Name
profile_acceleration
Object Code
VAR
Data Type
UINT32