![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 249](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119249.webp)
B
Diagnostic messages
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
249
Error group 32
Intermediate circuit fault
No.
Reaction
Message
Code
32-5
3282h
Brake chopper overload
configurable
Cause
The extent of utilisation of the brake chopper when quick dis
charge began was already in the range above 100%. Quick dis
charge took the brake chopper to the maximum load limit and was
prevented/aborted.
Measure
No action required.
32-6
3283h
Intermediate circuit discharge time exceeded
configurable
Cause
Intermediate circuit could not be quickly discharged. The internal
braking resistor may be faulty or, in the case of operation with an
external resistor, that resistor is not connected.
Measure
Check interface to the external braking resistor.
Alternatively, check whether the jumper for the internal braking
resistor is in place.
If the internal resistor has been activated and the jumper has been
set correctly, the internal braking resistor is probably faulty.
32-7
3284h
Power supply missing for controller enable
configurable
Cause
Controller enable was issued when the intermediate circuit was
still in its charging phase after mains voltage was applied and the
mains relay was not yet activated. The drive cannot be enabled in
this phase, because the drive is not yet firmly connected to the
mains (through the mains relay).
Measure
In the application, check whether the mains supply and control
ler enable signals were sent quickly one after the other.
32-8
3285h
Power supply failure during controller enable
QStop
Cause
Interruptions / failure in the power supply while the controller
enable was activated.
Measure
Check the power supply.
32-9
3286h
Phase failure
QStop
Cause
Failure of one or more phases (only in the case of three-phase
supply).
Measure
Check the power supply.