Device Control
154
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Status diagram: statuses
The following table lists all statuses and their meaning:
Name
Significance
NOT_READY_TO_SWITCH_ON
The motor controller performs a self-test. The CAN communication
does not work yet.
SWITCH_ON_DISABLED
The motor controller has completed its self-test. CAN
communication is possible.
READY_TO_SWITCH_ON
The motor controller waits until the digital inputs “output stage”
and “controller enable” are at 24 V. (Controller enable logic “Digital
input and CAN”).
SWITCHED_ON
1)
The output stage is switched on.
OPERATION_ENABLE
1)
Voltage to the motor is on, and the motor is regulated
corresponding to the operating mode.
QUICKSTOP_ACTIVE
1)
The Quick Stop Function is being executed
(
quick_stop_option_code). Voltage to the motor is on, and the
motor is regulated according to the quick stop function.
FAULT_REACTION_ACTIVE
1)
An error has occurred. With critical errors, the system immediately
switches into the Fault status. Otherwise, the action specified in
the fault_reaction_option_code is carried out. Voltage to the
motor is on, and the motor is regulated according to the fault
reaction function.
FAULT
An error has occurred. No voltage is applied to the motor.
1)
The output stage is switched on.