![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 149](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119149.webp)
5
Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
149
The response of the error can be changed in the object error_reaction_code. If the response falls below
the manufacturer's minimum response, it is limited to this minimum. The response actually set can be
determined by reading back.
Sub-Index
02
h
Description
error_reaction_code
Data Type
UINT8
Access
rw
PDO mapping
no
Units
–
Value Range
0, 1, 3, 5, 7, 8
Default Value
dependent on error_number
Value
Meaning
0
No action
1
Entry in the buffer
3
Warning on the 7-segments display and in the status word
5
Controller enable off
7
Braking with maximum current
8
Output stage off
Object 200F
h
: last_warning_code
Warnings are special events of the drive (e.g. a following error), which in contrast to an error should not
result in stopping of the drive. Warnings are displayed on the 7-segments display of the controller and
after that automatically reset by the controller.
The last warning that occurred can be read via the following object: Bit 15 displays thereby whether the
warning is currently still active.
Index
200F
h
Name
last_warning_code
Object Code
VAR
Data Type
UINT16
Access
ro
PDO mapping
yes
Units
–
Value Range
–
Default Value
–
Bit
Value
Meaning
0 … 3
000F
h
Sub-number of the warning
4 … 11
0FF0
h
Main number of the warning
15
8000
h
Warning is active