![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 225](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119225.webp)
B
Diagnostic messages
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
225
Error group 3
Motor over-temperature
No.
Reaction
Message
Code
3-1
4310h
Digital motor overtemperature
configurable
Cause
–
Motor overloaded, temperature too high.
–
Suitable sensor or sensor characteristics parameterised?
–
Sensor faulty?
Measure
Check parameterisation (current regulator, current limits).
Check the parameterisation of the sensor or the sensor charac
teristics.
If the error persists when the sensor is bypassed: device faulty.
3-2
4310h
Analogue motor overtemperature: Broken wire
configurable
Cause
The measured resistance value is above the threshold for wire
break detection.
Measure
Check the connecting cables of the temperature sensor for wire
breaks.
Check the parameterisation (threshold value) for wire break
detection.
3-3
4310h
Analogue motor overtemperature: Short circuit
configurable
Cause
The measured resistance value is below the threshold for short
circuit detection.
Measure
Check the connecting cables of the temperature sensor for wire
breaks.
Check the parameterisation (threshold value) for short circuit
detection.
Error group 4
Power section/intermediate circuit over-temperature
No.
Code
Message
Reaction
4-0
4210h
Power section overtemperature
configurable
Cause
Device is overheated
–
Is displayed temperature plausible?
–
Device fan faulty?
–
Device overloaded?
Measure
Check installation conditions; control cabinet fan filter dirty?
Check the cylinder sizing (due to possible overloading in con
tinuous duty).