B
Diagnostic messages
220
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
B.2
Error codes via CiA 301/402
Diagnostic messages
Code
No.
Message
Reaction
2311h
31-1
I²t-servo controller
Configurable
2312h
31-0
I²t-motor
Configurable
2313h
31-2
I²t-PFC
Configurable
2314h
31-3
I²t braking resistor
Configurable
2320h
06-0
Short circuit in output stage
PS off
06-1
Overload current brake chopper
PS off
3210h
07-0
Overvoltage in intermediate circuit
PS off
3220h
02-0
Undervoltage in intermediate circuit
Configurable
3280h
32-0
Intermediate circuit charging time exceeded
Configurable
3281h
32-1
Undervoltage for active PFC
Configurable
3282h
32-5
Brake chopper overload. Intermediate circuit could not be
discharged.
Configurable
3283h
32-6
Intermediate circuit discharge time exceeded
Configurable
3284h
32-7
Power supply missing for controller enable
Configurable
3285h
32-8
Power supply failure during controller enable
QStop
3286h
32-9
Phase failure
QStop
4210h
04-0
Power end stage over-temperature
Configurable
4280h
04-1
Intermediate circuit over-temperature
Configurable
4310h
03-0
Analogue motor over-temperature
QStop
03-1
Digital motor over-temperature
Configurable
03-2
Analogue motor over-temperature: broken cable
Configurable
03-3
Analogue motor over-temperature: short circuit
Configurable
5080h
90-0
Missing hardware components (SRAM)
PS off
90-2
Error when booting FPGA
PS off
90-3
Error at SD-ADU start
PS off
90-4
SD-ADU synchronisation error after start
PS off
90-5
SD-ADU not synchronous
PS off
90-6
IRQ0 (current regulator): trigger error
PS off
90-9
DEBUG firmware loaded
PS off
5114h
05-0
Failure of internal voltage 1
PS off
5115h
05-1
Failure of internal voltage 2
PS off
5116h
05-2
Failure of driver supply
PS off
5280h
21-0
Error 1 current measurement U
PS off
5281h
21-1
Error 1 current measurement V
PS off
5282h
21-2
Error 2 current measurement U
PS off
5283h
21-3
Error 2 current measurement V
PS off
5410h
05-3
Undervoltage dig. I/O
PS off
05-4
Overload current dig. I/O
PS off
5580h
26-0
Missing user parameter set
PS off