![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 148](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119148.webp)
5
Setting parameters
148
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
5.18
Error Management
Overview
The motor controllers of the CMMP family offer the option to change the error response of individual
events, e.g. the occurrence of a contouring error. Through this, the motor controller reacts differently if
a certain event occurs: Dependent on the setting, braking down can occur and the output stage is shut
off immediately, but also just a warning can be shown on the display.
For every event, a minimum reaction is intended by the manufacturer, which cannot be fallen below.
And so “critical” errors, such as 60-0 short circuit output stage, are not reparametrised, since here an
immediate switch-off is necessary to protect the motor controller from possible destruction.
If a lower error response is entered than is permissible for the respective error, the value is limited to
the lowest permissible error response. A list of all error numbers is found in chapter B
Description of the objects
Objects treated in this chapter
Index
Object
Name
Type
Attr.
2100
h
RECORD
error_management
ro
2100_01
h
VAR
error_number
UINT8
rw
2100_02
h
VAR
error_reaction_code
UINT8
rw
200F
h
VAR
last_warning_code
UINT16
ro
Object 2100
h
: error_management
Index
2100
h
Name
error_management
Object Code
RECORD
No. of Elements
2
The main error number whose response should be changed must be specified in the object error_num
ber. The main error number is normally specified before the hyphen (e.g. error 08-2, main error num
ber 8). For possible error numbers,
also chap. 3.5.
Sub-Index
01
h
Description
error_number
Data Type
UINT8
Access
rw
PDO mapping
no
Units
–
Value Range
1 … 96
Default Value
1