3
CANopen access procedure
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
29
Observe that parametrisation of the PDOs may generally only be changed when the net
work status (NMT) is not operational.
3.3.2
Objects for PDO Parametrisation
The motor controllers of the CMMP series have available a total of 4 transmit and 4 receive PDOs.
The individual objects for parametrisation of these PDOs are the same for all 4 TPDOs and all 4 RPDOs
respectively. For that reason, only the parameter description of the first TPDO is explicitly listed. The
meaning can also be used for the other PDOs, which are listed in table form in the following:
Index
1800
h
Name
transmit_pdo_parameter_tpdo1
Object Code
RECORD
No. of Elements
3
Sub-Index
01
h
Description
cob_id_used_by_pdo_tpdo1
Data Type
UINT32
Access
rw
PDO Mapping
no
Units
–
Value Range
181
h
… 1FF
h
, bit 30 and 31 may be set
Default Value
C0000181
h
Sub-Index
02
h
Description
transmission_type_tpdo1
Data Type
UINT8
Access
rw
PDO Mapping
no
Units
–
Value Range
0 … 8C
h
, FE
h
, FF
h
Default Value
FF
h
Sub-Index
03
h
Description
inhibit_time_tpdo1
Data Type
UINT16
Access
rw
PDO Mapping
no
Units
100 μs (i.e. 10 = 1ms)
Value Range
–
Default Value
0