![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 111](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119111.webp)
5
Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
111
Index
6065
h
Name
following_error_window
Object Code
VAR
Data Type
UINT32
Access
rw
PDO mapping
yes
Units
position units
Value Range
–
Default Value
9101 (9101/65536 R = 50°)
Object 6066
h
: following_error_time_out
If a contouring error longer than defined in this object occurs, the related bit 13 following_error is set in
the statusword.
Index
6066
h
Name
following_error_time_out
Object Code
VAR
Data Type
UINT16
Access
rw
PDO mapping
yes
Units
ms
Value Range
0 … 27314
Default Value
0
Object 60F4
h
: following_error_actual_value
The current contouring error can be read out via this object. This object is specified in user-defined
increments.
Index
60F4
h
Name
following_error_actual_value
Object Code
VAR
Data Type
INT32
Access
ro
PDO mapping
yes
Units
position units
Value Range
–
Default Value
–