![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 169](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119169.webp)
6
Device Control
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
169
Sub-Index
02
h
Description
FSM_vout_32_63
Data Type
UINT32
Access
ro
PDO Mapping
yes
Units
–
Value Range
–
Default Value
–
Bits 0..31 = VOUT32..63 of the safety module
Object 2602h: FSM_IO
Read the level at the inputs of the safety module
Index
2602
h
Name
FSM_io
Object Code
RECORD
No. of Elements
1
Sub-Index
01
h
Description
FSM_dig_io
Data Type
UINT32
Access
ro
PDO Mapping
yes
Units
–
Value Range
–
Default Value
–
FSM_dig_io
Bit
Signal
Description
Bit 0
LOUT48
Logical status DIN40 A/B
Bit 1
LOUT49
Logical status DIN41 A/B
Bit 2
LOUT50
Logical status DIN42 A/B
Bit 3
LOUT51
Logical status DIN43 A/B
Bit 4
LOUT52
Logical status DIN44
Bit 5
LOUT53
Logical status DIN45; mode selector switch (1 of 3)
Bit 6
LOUT54
Logical status DIN46; mode selector switch (1 of 3)
Bit 7
LOUT55
Logical status DIN47; mode selector switch (1 of 3)
Bit 8
LOUT56
Error acknowledgment via DIN48
Bit 9
LOUT57
Restart via DIN49