Sub-Index
02
h
Description
velocity_control_time
Data Type
UINT16
Access
rw
PDO mapping
no
Units
μs
Value Range
1 … 32000
Default Value
2000
Sub-Index
04
h
Description
velocity_control_filter_time
Data Type
UINT16
Access
rw
PDO mapping
no
Units
μs
Value Range
1 … 32000
Default Value
400
Object 2073
h
: velocity_display_filter_time
The filter time constant of the display speed actual value filter can be set via the object
velocity_display_filter_time.
Index
2073
h
Name
velocity_display_filter_time
Object Code
VAR
Data Type
UINT32
Access
rw
PDO mapping
no
Units
μs
Value Range
1000 … 50000
Default Value
20000
Please observe that the object velocity_actual_value_filtered is used for spinning protec
tion. With very large filter times, a spinning error is detected only with a corresponding
delay.