5.5
Current Regulator and Motor Adjustment
Caution
Incorrect settings of the current regulator parameters and current limits can destroy the
motor and, possibly, also the motor controller within a very short time!
Overview
The parameter set of the motor controller must be adapted for the connected motor and the set of
cables used. Affected are the following parameters:
Parameters
Dependencies
Nominal current
Dependent on the motor
Overload capacity
Dependent on the motor
Number of poles
Dependent on the motor
Current regulator
Dependent on the motor
Direction of
rotation
Dependent on the motor and on the phase sequence in the motor and angle
transmitter cable
Offset Angle
Dependent on the motor and on the phase sequence in the motor and angle
transmitter cable
Please observe that the direction of rotation and offset angle also depend on the cable set used. The
parameter sets therefore work only with identical cabling.
Caution
If the phase sequence is distorted in the motor or angle encoder cable, the result may
be positive feedback, so the speed in the motor cannot be regulated. The motor can
turn uncontrollably!
Description of the Objects
Index
Object
Name
Type
Attr.
6075
h
VAR
motor_rated_current
UINT32
rw
6073
h
VAR
max_current
UINT16
rw
604D
h
VAR
pole_number
UINT8
rw
6410
h
RECORD
motor_data
rw
60F6
h
RECORD
torque_control_parameters
rw
Affected objects from other chapters
Index
Object
Name
Type Chapter
2415
h
RECORD
current_limitation