![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 268](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119268.webp)
B
Diagnostic messages
268
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Error group 59
Internal safety module error (only CMMP-AS-...-M3)
No.
Reaction
Message
Code
59-4
80F4h
Error management: Too many errors
configurable
Cause
–
Too many errors have occurred simultaneously.
Measure
Clarify: What is the status of the installed safety module - does
it contain a valid parameter set?
Read out and analyse the log file of the basic unit via FCT.
Remedy causes of error step by step.
Install safety module with "delivery status" and perform com
missioning of basic unit.
If this is not available: Set factory settings in the safety module,
then copy data from the basic unit and perform complete valid
ation. Check whether the error occurs again.
59-5
80F5h
Diagnosis Memory writing error
configurable
Cause
Subsequent error if internal communication is disrupted.
–
Basic unit not ready for operation, faulty or memory error.
Measure
Check the function of the basic unit
Generate an error in the basic unit, e.g. by unplugging the posi
tion encoder, and check whether the basic unit writes an entry
to the log file.
Module or basic unit faulty; replace.
59-6
80F6h
Error on saving parameter set
configurable
Cause
–
Voltage interruption / power off while parameters were being
saved.
Measure
Maintain a voltage supply of 24 V throughout the parameterisa
tion session.
Once the error has occurred, parameterise the module again
and validate the parameter set again.
59-7
80F7h
FLASH checksum error
configurable
Cause
–
Voltage interruption / power off while parameters were being
saved.
–
Flash memory in safety module corrupted (e.g. by extreme
malfunctions).
Measure
Check whether the error recurs after a reset. If it does:
Parameterise the module again and validate the parameter set
again. If the error remains:
Module is faulty; replace.