![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 116](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119116.webp)
5
Setting parameters
116
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
5.8
Setpoint value limitation
Description of the objects
Objects treated in this chapter
Index
Object
Name
Type
Attr.
2415
h
RECORD
current_limitation
rw
2416
h
RECORD
speed_limitation
rw
Object 2415
h
: current_limitation
With the object group current_limitation, the maximum peak current for the motor can be limited in the
operating modes profile_position_mode, interpolated_position_mode, homing_mode und
velocity_mode, which makes a torque-limited speed operation possible. The setpoint value source of
the limit torque is specified via the object limit_current_input_channel. Here, a choice can be made
between specification of a direct setpoint value (fixed value) or specification via an analogue input.
Depending on the source chosen, either the limit torque (source = fixed value) or the scaling factor for
the analogue inputs (source = analogue input) is specified via the object limit_current. In the first case,
the torque-proportional current, in mA, is limited directly; in the second case, the current that should
correspond to a voltage of 10 V is specified, in mA.
Index
2415
h
Name
current_limitation
Object Code
RECORD
No. of Elements
2
Sub-Index
01
h
Description
limit_current_input_channel
Data Type
UINT8
Access
rw
PDO mapping
no
Units
–
Value Range
0 … 4
Default Value
0
Sub-Index
02
h
Description
limit_current
Data Type
INT32
Access
rw
PDO mapping
no
Units
mA
Value Range
–
Default Value
0