![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 245](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119245.webp)
B
Diagnostic messages
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
245
Error group 26
Internal data error
No.
Reaction
Message
Code
26-6
5586h
Missing position data sets
PSoff
Cause
Position data sets incomplete or corrupted.
Measure
Load the factory settings or
save the current parameters again so that the position data is
written again.
26-7
-
Faulty data tables (CAM)
PSoff
Cause
Data for the cam disc is corrupted.
Measure
Load factory settings.
Reload the parameter set if necessary.
If the error persists, contact Technical Support.
Error group 27
Following error monitoring
No.
Code
Message
Reaction
27-0
8611h
Following error warning threshold
configurable
Cause
–
Motor overloaded? Check motor capacity.
–
Acceleration or braking ramps are set too steep.
–
Motor blocked? Commutation angle correct?
Measure
Check the parameterisation of the motor data.
Check the parameterisation of the following error.
Error group 28
Operating hour counter
No.
Code
Message
Reaction
28-0
FF01h
Missing operating hour counter
configurable
Cause
No record for an operating hour counter could be found in the
parameter block. A new operating hour counter was created. Oc
curs during initial start-up or a processor change.
Measure
Warning only, no further action required.
28-1
FF02h
Operating hour counter: Write error
configurable
Cause
The data block in which the operating hour counter is stored could
not be written to. Cause unknown; possibly problems with the
hardware.
Measure
Warning only, no further action required.
If the error occurs again, the hardware may be faulty.