![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 109](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119109.webp)
5
Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
109
Object 6062
h
: position_demand_value
The current position setpoint value can be read out via this object. The curve generator feeds this into
the position controller.
Index
6062
h
Name
position_demand_value
Object Code
VAR
No. of Elements
INT32
Access
ro
PDO mapping
yes
Units
position units
Value Range
–
Default Value
–
Object 202D
h
: position_demand_sync_value
The target position of the synchronisation encoder can be read out via this object. This is defined
through the object 2022
h
synchronization_encoder_select (
chap. 5.11). This object is specified in
user-defined increments.
Index
202D
h
Name
position_demand_sync_value
Object Code
VAR
Data Type
INT32
Access
ro
PDO mapping
no
Units
position units
Value Range
–
Default Value
–