![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 91](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119091.webp)
5
Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
91
Index
6510
h
Name
drive_data
Object Code
RECORD
No. of Elements
51
Sub-Index
10
h
Description
enable_logic
Data Type
UINT16
Access
rw
PDO mapping
no
Units
–
Value Range
0 … 2
Default Value
0
Value
Meaning
0
Digital inputs output stage controller enable
1
Digital inputs output stage controller parametrisation interface
2
Digital inputs output stage controller CAN
Object 6510
h
_30
h
: pwm_frequency
The switching losses of the output stage are proportional to the switching frequency of the power
transistors. With the devices of the CMMP family, cutting the normal pulse-width modulation frequency
in half can produce more output. But the current ripple factor caused by the output stage rises.
Reversing is only possible when the output stage is switched off.
Sub-Index
30
h
Description
pwm_frequency
Data Type
UINT16
Access
rw
PDO mapping
no
Units
–
Value Range
0, 1
Default Value
0
Value
Meaning
0
Standard output stage frequency
1