Object 6080
h
: max_motor_speed
The object max_motor_speed gives the highest allowed speed for the motor in min
-1
. The object is
used to protect the motor and can be taken from the motor technical data. The speed setpoint value is
limited to this value.
Index
6080
h
Name
max_motor_speed
Object Code
VAR
Data Type
UINT16
Access
rw
PDO mapping
yes
Units
min
-1
Value Range
0 … 32768 min
-1
Default Value
32768 min
-1
Object 60FF
h
: target_velocity
The object target_velocity is the setpoint specification for the ramp generator.
Index
60FF
h
Name
target_velocity
Object Code
VAR
Data Type
INT32
Access
rw
PDO mapping
yes
Units
speed units
Value Range
–
Default Value
–
7.6
Speed ramps
Selected as modes_of_operation - profile_velocity_mode; the setpoint value ramp is also activated.
And so it is possible to limit a jump-like setpoint change to a specific speed change per time via the
objects profile_acceleration and profile_deceleration. The controller not only permits specification of
different values for braking deceleration and acceleration, but also differentiation between positive and
negative speed. The following illustration depicts this behaviour: