7
Operating modes
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
179
Sub-Index
02
h
Description
speed_during_search_for_zero
Access
rw
PDO mapping
yes
Units
speed units
Value Range
–
Default Value
10 min
-1
If bit 6 is set in the object compatibility_control, (
chap. 5.2), after homing travel to zero
is performed.
If this bit is set and the object speed_during_search_for_switch is written, both the speed
for the switch search and the speed for the travel to zero are written.
Object 609A
h
: homing_acceleration
The object homing_acceleration determines the acceleration that is used during homing for all
acceleration and braking processes.
Index
609A
h
Name
homing_acceleration
Object Code
VAR
Data Type
UINT32
Access
rw
PDO mapping
yes
Units
acceleration units
Value Range
–
Default Value
1000 min
-1
/s
Object 2045
h
: homing_timeout
Homing can be monitored for maximum execution time. In addition, the maximum execution time can
be specified with the object homing_timeout. If this time is exceeded without homing having been
ended, error 11-3.
Index
2045
h
Name
homing_timeout
Object Code
VAR
Data Type
UINT16
Access
rw
PDO mapping
no
Units
ms
Value Range
0 (off ), 1 … 65535
Default Value
60000