Error group 9
Error in the angle encoder parameter set
No.
Reaction
Message
Code
9-4
-
EEPROM data: User-specific configuration faulty
configurable
Cause
Only for special motors:
The plausibility check returns an error, e.g. because the motor was
repaired or replaced.
Measure
If motor repaired: Carry out homing again and save in the angle
encoder, after that (!) save in the motor controller.
If motor replaced: Parameterise the controller again, then carry
out homing again and save in the angle encoder, after that (!)
save in the motor controller.
9-5
-
Read/Write Error EEPROM parameter data
configurable
Cause
Error occurred during reading or writing data to the internal en
coder parameter set.
Measure
Occurs with Hiperface encoders: A data field of the encoder is not
suitable to be read from the firmware or data can not be written for
unknown reasons.
Send motor to the manufacturer for inspection.
9-7
73A5h
Encoder EEPROM is write protected
configurable
Cause
Data cannot be saved in the EEPROM of the angle encoder.
Occurs with Hiperface encoders.
Measure
A data field in the encoder EEPROM is write-protected (e.g. after
operation on a motor controller of another manufacturer). No solu
tion possible, encoder memory must be unlocked with a corres
ponding parameterisation tool (from manufacturer).
9-9
73A6h
Memory size of encoder EEPROM too small
configurable
Cause
It is not possible to save all the data in the EEPROM of the angle
encoder.
Measure
Reduce the number of data records to be saved. Please read
the documentation or contact Technical Support.
Error group 10
Exceeding max. speed
No.
Code
Message
Reaction
10-0
-
Overspeed
configurable
Cause
–
Motor racing ("spinning") because the commutation angle
offset is incorrect.
–
Motor is parameterised correctly, but the limit for spinning pro
tection is set too low.
Measure
Check the commutation angle offset.
Check the parameterisation of the limit value.