![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 118](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119118.webp)
5
Setting parameters
118
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Value
Meaning
0
No limitation
1
AIN0
2
AIN1
3
AIN2
4
Fieldbus (selector B)
5.9
Encoder Adjustments
Overview
This chapter describes the configuration of the angle encoder input [X2A], [X2B] and incremental
input [X10].
Caution
Incorrect angle encoder settings can cause the drive to turn uncontrollably and possibly
destroy parts of the system.
Description of the objects
Objects treated in this chapter
Index
Object
Name
Type
Attr.
2024
h
RECORD
encoder_x2a_data_field
ro
2024
h
_01
h
VAR
encoder_x2a_resolution
UINT32
ro
2024
h
_02
h
VAR
encoder_x2a_numerator
INT16
rw
2024
h
_03
h
VAR
encoder_x2a_divisor
INT16
rw
2025
h
RECORD
encoder_x10_data_field
ro
2025
h
_01
h
VAR
encoder_x10_resolution
UINT32
rw
2025
h
_02
h
VAR
encoder_x10_numerator
INT16
rw
2025
h
_03
h
VAR
encoder_x10_divisor
INT16
rw
2025
h
_04
h
VAR
encoder_x10_counter
UINT32
ro
2026
h
RECORD
encoder_x2b_data_field
ro
2026
h
_01
h
VAR
encoder_x2b_resolution
UINT32
rw
2026
h
_02
h
VAR
encoder_x2b_numerator
INT16
rw
2026
h
_03
h
VAR
encoder_x2b_divisor
INT16
rw
2026
h
_04
h
VAR
encoder_x2b_counter
UINT32
ro