![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119034.webp)
3
CANopen access procedure
34
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
3. Receive PDO
Index
Comment
Type
Acc.
Default Value
1402
h
_00
h
number of entries
UINT8
ro
02
h
1402
h
_01
h
COB-ID used by PDO
UINT32
rw
C0000401
h
1402
h
_02
h
transmission type
UINT8
rw
FF
h
1602
h
_00
h
number of mapped objects
UINT8
rw
02
h
1602
h
_01
h
first mapped object
UINT32
rw
60400010
h
1602
h
_02
h
second mapped object
UINT32
rw
607A0020
h
1602
h
_03
h
third mapped object
UINT32
rw
00000000
h
1602
h
_04
h
fourth mapped object
UINT32
rw
00000000
h
4. Receive PDO
Index
Comment
Type
Acc.
Default Value
1403
h
_00
h
number of entries
UINT8
ro
02
h
1403
h
_01
h
COB-ID used by PDO
UINT32
rw
C0000501
h
1403
h
_02
h
transmission type
UINT8
rw
FF
h
1603
h
_00
h
number of mapped objects
UINT8
rw
02
h
1603
h
_01
h
first mapped object
UINT32
rw
60400010
h
1603
h
_02
h
second mapped object
UINT32
rw
60FF0020
h
1603
h
_03
h
third mapped object
UINT32
rw
00000000
h
1603
h
_04
h
fourth mapped object
UINT32
rw
00000000
h
3.3.3
Activation of PDOs
For the motor controller to send or receive PDOs, the following points must be met:
–
The object number_of_mapped_objects must not equal zero.
–
In the object cob_id_used_for_pdos, bit 31 must be deleted.
–
The communication status of the motor controller must be operational (
Management: NMT-Service)
To parametrise PDOs, the following points must be met:
–
The communication status of the motor controller must not be operational.