![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 146](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119146.webp)
5
Setting parameters
146
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Object 6510
h
_B3
h
: cycletime_trajectory_generator
Through the object cycletime_trajectory_generator, the cycle time of the position controller in micro
seconds can be read.
Sub-Index
B3
h
Description
cycletime_trajectory_generator
Data Type
UINT32
Access
ro
PDO mapping
no
Units
μs
Value Range
–
Default Value
000003E8
h
Object 6510
h
_C0
h
: commissioning_state
The commissioning_state object is written by the parameterisation software if certain parameterisa
tions have been executed (e.g. nominal current). After delivery and after restore_default_parameter,
this object includes a “0”. In this case, an “A” is displayed on the 7-segments display of the motor con
troller to point out that this device has not been parameterised yet. If the motor controller is paramet
erised completely under CANopen, at least one bit in this object must be set to suppress the display
“A”. Of course, if required it is also possible to use this object in order to notice the status of the con
troller parameterisation. Observe in this case that the parameterisation software also accesses this
object.
Sub-Index
C0
h
Description
commissioning_state
Data Type
UINT32
Access
rw
PDO mapping
no
Units
–
Value Range
–
Default Value
0