![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 254](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119254.webp)
B
Diagnostic messages
254
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Error group 43
Hardware limit switch
No.
Reaction
Message
Code
43-1
8082h
Limit switch: Positive setpoint value blocked
configurable
Cause
Positive hardware limit switch reached.
Measure
Check parameterisation, wiring and limit switches.
43-2
8083h
Limit switch: Positioning suppressed
configurable
Cause
–
The drive has left the designated range of motion.
–
Technical defect in the system?
Measure
Check the designated range of motion.
Error group 44
Cam disc error
No.
Code
Message
Reaction
44-0
-
Error in Cam data tables
configurable
Cause
The cam disc to be started is not available.
Measure
Check transferred cam disc no.
Correct parameterisation.
Correct programming.
44-1
-
Cam Disc: General error homing
configurable
Cause
–
Start of a cam disc, but the drive is not yet referenced.
Measure
Carry out homing.
Cause
–
Start homing with active cam disk.
Measure
Deactivate cam disc. Then restart cam disc, if necessary.
Error group 47
Setting-up
No.
Code
Message
Reaction
47-0
-
Timeout setup mode
configurable
Cause
Failed to fall below the speed required for setting-up within time
allowed.
Measure
Check processing of the request on the control side.
Error group 48
Homing required
No.
Code
Message
Reaction
48-0
-
Please enforce homing run!
QStop
Cause
An attempt is being made to switch to the speed control or torque
control operating mode or to issue the controller enable in one of
these operating modes, although the drive requires a valid refer
ence position for this.
Measure
Carry out homing.