Error group 56
Measuring of actual value 2 (only CMMP-AS-...-M3)
No.
Reaction
Message
Code
56-9
-
Error Cross comparison encoder evaluation
configurable
Cause
Cross-comparison between μC1 and μC2 has detected an angle
difference or speed difference or difference in capture times for the
position encoders.
Measure
Timing disrupted. If the error occurs against after a reset, the
safety module is presumably faulty.
Error group 57
Input/output error (only CMMP-AS-...-M3)
No.
Code
Message
Reaction
57-0
80E1h
Self test I/O error (internal/external)
configurable
Cause
–
Error at outputs DOUT40 ... DOUT42 (detection by test pulses).
–
Internal error of digital inputs DIN40 ... DIN49 (via internal test
signals).
–
Error at brake output at X6 (signalling, detection by test
pulses).
–
Internal error of brake output (via internal test signals).
–
Internal error of digital outputs DOUT40 DOUT42 (via internal
test signals).
Measure
Check the connection wiring for the digital outputs DOUT40 ...
DOUT42 (short circuit, cross circuit, etc.).
Check the connection wiring for the brake (short circuit, cross
circuit, etc.).
Brake connection: The error may occur with longer motor
cables if:
1. The brake output X6 was configured for the brake (this is the
case with factory settings!) and
2. A motor without a holding brake is used and the brake connec
tion lines in the motor cable are terminated at X6. In this case:
Disconnect the brake connection lines at X6.
If there is not error in the connection wiring, there may be an
internal error in the module (check by swapping the module).