![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 128](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119128.webp)
5
Setting parameters
128
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Sub-Index
03
h
Description
analog_input_voltage_ch_2
Access
ro
PDO mapping
no
Units
mV
Value Range
–
Default Value
–
Object 2401
h
: analog_input_offset (offset for analogue inputs)
Through the object group
analog_input_offset
, the offset voltage in millivolts for the respective inputs
can be set or read. With help of the offset, direct voltage that may be present can be compensated. A
positive offset compensates thereby for a positive input voltage.
Index
2401
h
Name
analog_input_offset
Object Code
ARRAY
No. of Elements
3
Data Type
INT32
Sub-Index
01
h
Description
analog_input_offset_ch_0
Access
rw
PDO mapping
no
Units
mV
Value Range
–10000 … 10000
Default Value
0
Sub-Index
02
h
Description
analog_input_offset_ch_1
Access
rw
PDO mapping
no
Units
mV
Value Range
–10000 … 10000
Default Value
0
Sub-Index
03
h
Description
analog_input_offset_ch_2
Access
rw
PDO mapping
no
Units
mV
Value Range
–10000 … 10000
Default Value
0