B
Diagnostic messages
252
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Error group 36
Parameter
No.
Code
Message
Reaction
36-0
6320h
Parameter was limited
configurable
Cause
An attempt was made to write a value which was outside the per
mitted limits, so the value was limited.
Measure
Check the user parameter set.
36-1
6320h
Parameter was not accepted
configurable
Cause
An attempt was made to write to an object which is "read only" or
is not write-capable in the current status (e.g. with controller en
able active).
Measure
Check the user parameter set.
Error group 40
Software limits
No.
Code
Message
Reaction
40-0
8612h
Negative software limit reached
configurable
Cause
The position setpoint has reached or exceeded the negative soft
ware limit switch.
Measure
Check target data.
Check the positioning range.
40-1
8612h
Positive software limit reached
configurable
Cause
The position setpoint has reached or exceeded the positive soft
ware limit switch.
Measure
Check target data.
Check the positioning range.
40-2
8612h
Positioning beyond negative software limit suppressed
configurable
Cause
Start of a positioning task was suppressed because the target lies
behind the negative software limit switch.
Measure
Check target data.
Check the positioning range.
40-3
8612h
Positioning beyond positive software limit suppressed
configurable
Cause
The start of a positioning task was suppressed because the target
lies behind the positive software limit switch.
Measure
Check target data.
Check the positioning range.
Error group 41
Record sequence
No.
Code
Message
Reaction
41-0
-
Record sequence: Synchronisation error
configurable
Cause
Start of synchronisation without prior sampling pulse.
Measure
Check parameterisation of the lead section.