![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 226](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119226.webp)
B
Diagnostic messages
226
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Error group 4
Power section/intermediate circuit over-temperature
No.
Reaction
Message
Code
4-1
4280h
Intermediate circuit overtemperature
configurable
Cause
Device is overheated
–
Is displayed temperature plausible?
–
Device fan faulty?
–
Device overloaded?
Measure
Check installation conditions; control cabinet fan filter dirty?
Check the cylinder sizing (due to possible overloading in con
tinuous duty).
Error group 5
Internal voltage supply
No.
Code
Message
Reaction
5-0
5114h
Failure of internal voltage 1
PSoff
Cause
Internal power supply monitor has detected undervoltage. This is
either due to an internal defect or an overload/short circuit caused
by connected peripherals.
Measure
Check digital outputs and brake output for short circuit or spe
cified load.
Separate device from the entire peripheral equipment and
check whether the error is still present after reset. If so, an
internal defect is present
Repair by the manufacturer.
5-1
5115h
Failure of internal voltage 2
PSoff
Cause
Internal power supply monitor has detected undervoltage. This is
either due to an internal defect or an overload/short circuit caused
by connected peripherals.
Measure
Check digital outputs and brake output for short circuit or spe
cified load.
Separate device from the entire peripheral equipment and
check whether the error is still present after reset. If so, an
internal defect is present
Repair by the manufacturer.
5-2
5116h
Failure of driver supply
PSoff
Cause
Internal power supply monitor has detected undervoltage. This is
either due to an internal defect or an overload/short circuit caused
by connected peripherals.
Measure
Check digital outputs and brake output for short circuit or spe
cified load.
Separate device from the entire peripheral equipment and
check whether the error is still present after reset. If so, an
internal defect is present
Repair by the manufacturer.