![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 206](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119206.webp)
7
Operating modes
206
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Object 2074
h
: velocity_actual_value_filtered
A filtered actual speed value can be read via the object velocity_actual_value_filtered, but it should
only be used for display purposes.
In contrast to velocity_actual_value, velocity_actual_value_filtered is not used for control, but for
spinning protection of the controller. The filter time constant can be set via the object 2073
h
(velocity_display_filter_time).
Object 2073h: velocity_display_filter_time
Index
2074
h
Name
velocity_actual_value_filtered
Object Code
VAR
Data Type
INT32
Access
ro
PDO mapping
yes
Units
speed units
Value Range
–
Default Value
–
Filter
internal velocity value
velocity_display_filter_time (2073
h
)
velocity_control_filter_time (60F9
h
_04
h
)
Filter
velocity_actual_value (606C
h
)
[speed units]
velocity_actual_value_filtered
(2074
h
)
[speed units]
Fig. 7.10