![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119070.webp)
4
EtherCAT interface
70
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
<EtherCATInfo Version=“0.2“>
<Vendor>
<Id>#x1D</Id>
<Name>Festo AG</Name>
<ImageData16x14>424DD60200......</ImageData16x14>
</Vendor>
<Descriptions>
<Groups>
<Group SortOrder=“1“>
<Type>Festo Electric-Drives</Type>
<Name LcId=“1033“>Festo Electric-Drive</Name>
</Group>
</Groups>
<Devices>
<Device Physics=“YY“>
</Device>
</Devices>
</Descriptions>
</EteherCATInfo>
The following brief rules must be observed for the structure of an XML file:
–
Each node must have a unique name.
–
Each node opens with <node name> and closes with </node name>.
The device description file for the motor controller CMMP-AS-...-M3 under EtherCAT CoE is divided into
the following sub-items:
Node name
Significance
Adaptable
Vendor
This node contains the name and the ID of the manufacturer of the
device to which this description file belongs. It also contains the
binary code of a bitmap with the manufacturer's logo.
No
Description
This sub-item contains the actual device description including the
configuration and initialisation.
Partially
Group
This node contains the assignment of the device to a device group.
These groups are specified and may not be changed by the user.
No
Devices
This sub-item contains the actual description of the device.
Partially
Tab. 4.16 Nodes of the device description file
The following table describes only the subnodes of the “Description” node that are required for para
meterisation of the motor controller CMMP-AS-...-M3 under CoE. All other nodes are fixed and may not