Setting parameters
112
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Object 60FA
h
: control_effort
The output variable of the position controller can be read via this object. This value is internally fed to
the speed regulator as setpoint value.
Index
60FA
h
Name
control_effort
Object Code
VAR
Data Type
INT32
Access
ro
PDO mapping
yes
Units
speed units
Value Range
–
Default Value
–
Object 6067
h
: position_window
With the object
position_window
, a symmetrical area is defined around the target position
(target_position). If the actual position value (position_actual_value) lies within this area for a certain
time, the target position (target_position) is considered reached.
Index
6067
h
Name
position_window
Object Code
VAR
Data Type
UINT32
Access
rw
PDO mapping
yes
Units
position units
Value Range
–
Default Value
1820 (1820/65536 R = 10°)