![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 89](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119089.webp)
5
Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
89
Object 607E
h
: polarity
The algebraic sign of the position and speed values of the motor controller can be set with the corres
ponding polarity_flag. This can serve to invert the motor's direction of rotation with the same setpoint
values.
In most applications, it makes sense to set the position_polarity_flag and the velocity_polarity_flag to
the same value.
Setting of the polarity_flag influences only parameters when reading and writing. Parameters already
present in the motor controller are not changed.
Index
607E
h
Name
polarity
Object Code
VAR
Data Type
UINT8
Access
rw
PDO mapping
yes
Units
–
Value Range
40
h
, 80
h
, C0
h
Default Value
0
Bit
Value
Name
Meaning
6
40
h
velocity_polarity_flag
0: multiply by 1 (default)
1: multiply by -1 (inverse)
7
80
h
position_polarity_flag
0: multiply by 1 (default)
1: multiply by -1 (inverse)